60 SERIES |
30 SERIES |
15 SERIES |
12 SERIES |
6 SERIES |
Name of Model |
SAT-60A |
ST-60A |
PC-60A |
SAT-30A |
ST-30A |
PC-30A |
ST-15 |
PC-15 |
NB-12DX |
NB-12 |
NB-6DX |
NB-6* |
|
|
|
|
|
|
Amount of Accommodations |
60 pieces of
Tray (*1) |
30 pieces of
Tray (*1) |
15 pieces of
Tray (*1) |
12 pieces of
Tray (*1) |
6 pieces of
Tray (*1) |
Machine Size (W*D*H) |
370*158*193
cm |
183*140*193
cm |
114*128*191
cm |
69*167*180
cm |
69*167*149
cm |
Necessary Electric Power/Voltage |
640W/
AC100V-single |
410W/
AC100V-single |
200W/
AC100V-single |
150W/
AC100V-single |
130W/
AC100V-single |
Standard Heat Source/Fuel |
Oil Burner(GPN-9)/
Light Oil |
Oil Burner(SG-10)/
Light Oil |
Oil Burner(SG-6)/
Light Oil |
Amount of the Maximum Combustion |
8.3L/h |
5.0L/h |
3.7L/h |
3.1L/h |
2.4L/h |
Standard Oil Tank |
98L |
98L |
40L |
Chimney Caliber/material |
160mm/SUS430 |
120mm/SUS430 |
120mm/SUS430 |
120mm/SUS430 |
100mm/SUS430 |
Fan Caliber/watt |
50cm |
40cm |
35cm |
30cm |
25cm |
Hot-wind Generation System |
Indirect Formula by
Heat Exchanger |
Indirect Formula by
Heat Exchanger |
Indirect Formula by
Heat Exchanger |
Main Safeguard |
Flame-eye and
Overheating Thermostat |
Flame-eye and
Overheating Thermostat |
Flame-eye and
Overheating Thermostat |
Main Material of Drying Box |
Heat Insulation Panel |
Heat Insulation Panel |
SPCC |
SPCC |
SPCC |
Standard Control Unit |
CPC(*2)& Dumper Drive Unit |
ST type |
PC type |
CPC(*2)& Dumper Drive Unit |
ST type |
PC type |
STE type |
PCS type |
STE type |
PCS type |
STE type |
PCS type |
Temperature Control |
Automatic Control in
two stages |
Automatic Control in
two stages |
Automatic |
Automatic |
Automatic |
Process Control of Temperature |
Automatic(*3) |
Manual |
Manual |
Automatic(*3) |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Process Control of Intake and Exhaust |
Automatic(*4) |
Manual |
Manual |
Automatic(*4) |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Process Control of Fan |
Automatic(*5) |
Manual |
- |
Automatic(*5) |
Manual |
- |
Manual |
- |
Manual |
- |
Manual |
- |
Process Control of Dryness Time |
Automatic(*6) |
Manual |
Manual |
Automatic(*6) |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
|
|
|
|
note |
The superscription is present specification January first, 2002. There
is no a preliminary announcement, and the specification may be changed. |
note*1
|
Standard net tray / size : 120cm*60cm*5cm / mesh : 3.2cm*0.8cm / material
: polypropylene
|
note*2 |
CPC:Computed Program Controller / The original control board incorporating
the control program by the computer of our company.There are eight kinds
of programs. (six programs are pre-setup. two can be set up arbitrary) |
note*3 |
The temperature inside a dryness box is controlled by the specified program.
Temperature rises continuously rather than is gradual. |
note*4 |
Intake /exhaust system are controlled by the specified program in three
steps (opening, half-circulation, circulation) of the state. |
note*5 |
A fan's number of rotations is controlled by the specified program in three
steps of the state. |
note*6 |
Dryness time is controlled by the specified program. (Max, 99 hours) |
|
|
|
|